4.7 Article

Application of Micro-Computed Tomography With Iodine Staining to Cardiac Imaging, Segmentation, and Computational Model Development

期刊

IEEE TRANSACTIONS ON MEDICAL IMAGING
卷 32, 期 1, 页码 8-17

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2012.2209183

关键词

Animal models and imaging; heart; tissue modelling; X-ray imaging and computed tomography

资金

  1. British Heart Foundation U.K. [PG/10/69/28524]
  2. Engineering and Physical Sciences Research Council U.K. [EP/F007906, EP/I029826/1]
  3. NIHR Manchester Biomedical Research Centre, U.K.
  4. British Heart Foundation [RG/11/18/29257, PG/10/69/28524] Funding Source: researchfish
  5. Engineering and Physical Sciences Research Council [EP/I02249X/1] Funding Source: researchfish
  6. Medical Research Council [G0701785] Funding Source: researchfish
  7. National Institute for Health Research [ACF-2007-06-003] Funding Source: researchfish
  8. EPSRC [EP/I02249X/1] Funding Source: UKRI
  9. MRC [G0701785] Funding Source: UKRI

向作者/读者索取更多资源

Micro-computed tomography (micro-CT) has been widely used to generate high-resolution 3-D tissue images from small animals nondestructively, especially for mineralized skeletal tissues. However, its application to the analysis of soft cardiovascular tissues has been limited by poor inter-tissue contrast. Recent ex vivo studies have shown that contrast between muscular and connective tissue in micro-CT images can be enhanced by staining with iodine. In the present study, we apply this novel technique for imaging of cardiovascular structures in canine hearts. We optimize the method to obtain high-resolution X-ray micro-CT images of the canine atria and its distinctive regions-including the Bachmann's bundle, atrioventricular node, pulmonary arteries and veins-with clear inter-tissue contrast. The imaging results are used to reconstruct and segment the detailed 3-D geometry of the atria. Structure tensor analysis shows that the arrangement of atrial fibers can also be characterized using the enhanced micro-CT images, as iodine preferentially accumulates within the muscular fibers rather than in connective tissues. This novel technique can be particularly useful in nondestructive imaging of 3-D cardiac architectures from large animals and humans, due to the combination of relatively high speed (similar to 1 h/per scan of the large canine heart) and high voxel resolution (36 mu M) provided. In summary, contrast micro-CT facilitates fast and nondestructive imaging and segmenting of detailed 3-D cardiovascular geometries, as well as measuring fiber orientation, which are crucial in constructing biophysically detailed computational cardiac models.