4.7 Article

Separate Magnitude and Phase Regularization via Compressed Sensing

期刊

IEEE TRANSACTIONS ON MEDICAL IMAGING
卷 31, 期 9, 页码 1713-1723

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2012.2196707

关键词

Compressed sensing (CS); image reconstruction; magnetic resonance imaging (MRI); regularization

资金

  1. National Institutes of Health [P01 CA87634, R01 NS58576]

向作者/读者索取更多资源

Compressed sensing (CS) has been used for accelerating magnetic resonance imaging acquisitions, but its use in applications with rapid spatial phase variations is challenging, e. g., proton resonance frequency shift (PRF-shift) thermometry and velocity mapping. Previously, an iterative MRI reconstruction with separate magnitude and phase regularization was proposed for applications where magnitude and phase maps are both of interest, but it requires fully sampled data and unwrapped phase maps. In this paper, CS is combined into this framework to reconstruct magnitude and phase images accurately from undersampled data. Moreover, new phase regularization terms are proposed to accommodate phase wrapping and to reconstruct images with encoded phase variations, e. g., PRF-shift thermometry and velocity mapping. The proposed method is demonstrated with simulated thermometry data and in vivo velocity mapping data and compared to conventional phase corrected CS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据