4.7 Article

LOGISMOS-Layered Optimal Graph Image Segmentation of Multiple Objects and Surfaces: Cartilage Segmentation in the Knee Joint

期刊

IEEE TRANSACTIONS ON MEDICAL IMAGING
卷 29, 期 12, 页码 2023-2037

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2010.2058861

关键词

Knee cartilage segmentation; LOGISMOS; multi-layered graph search; optimal multiobject multisurface segmentation; osteoarthritis

资金

  1. National Institutes of Health (NIH) [R01-EB004640, R44-AR052983, P50 AR055533, N01-AR-2-2258, N01-AR-2-2259, N01-AR-2-2260, N01-AR-2-2261, N01-AR-2-2262]
  2. National Science Foundation (NSF) [CCF-0830402, CCF-0844765]
  3. Merck Research Laboratories
  4. Novartis Pharmaceuticals Corporation
  5. GlaxoSmithKline
  6. Pfizer, Inc.
  7. Division of Computing and Communication Foundations
  8. Direct For Computer & Info Scie & Enginr [0844765] Funding Source: National Science Foundation

向作者/读者索取更多资源

A novel method for simultaneous segmentation of multiple interacting surfaces belonging to multiple interacting objects, called LOGISMOS (layered optimal graph image segmentation of multiple objects and surfaces), is reported. The approach is based on the algorithmic incorporation of multiple spatial inter-relationships in a single n-dimensional graph, followed by graph optimization that yields a globally optimal solution. The LOGISMOS method's utility and performance are demonstrated on a bone and cartilage segmentation task in the human knee joint. Although trained on only a relatively small number of nine example images, this system achieved good performance. Judged by dice similarity coefficients (DSC) using a leave-one-out test, DSC values of 0.84 +/- 0.04, 0.80 +/- 0.04 and 0.80 +/- 0.04 were obtained for the femoral, tibial, and patellar cartilage regions, respectively. These are excellent DSC values, considering the narrow-sheet character of the cartilage regions. Similarly, low signed mean cartilage thickness errors were obtained when compared to a manually-traced independent standard in 60 randomly selected 3-D MR image datasets from the Osteoarthritis Initiative database-0.11 +/- 0.24, 0.05 +/- 0.23, and 0.03 +/- 0.17 mm for the femoral, tibial, and patellar cartilage thickness, respectively. The average signed surface positioning errors for the six detected surfaces ranged from 0.04 +/- 0.12 mm to 0.16 +/- 0.22 mm. The reported LOGISMOS framework provides robust and accurate segmentation of the knee joint bone and cartilage surfaces of the femur, tibia, and patella. As a general segmentation tool, the developed framework can be applied to a broad range of multiobject multisurface segmentation problems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据