4.7 Article

Automatic Segmentation and Quantitative Analysis of the Articular Cartilages From Magnetic Resonance Images of the Knee

期刊

IEEE TRANSACTIONS ON MEDICAL IMAGING
卷 29, 期 1, 页码 55-64

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2009.2024743

关键词

Bone; cartilage; deformable models; knee; magnetic resonance imaging (MRI); nonrigid registration; quantitative analysis; segmentation; shape models; surface area; thickness; thickness models; tissue classification; validation; volume; watershed

资金

  1. CIMIT
  2. NMSS [RG 3478A2/2]
  3. NIH [R03 CA126466, R01 RR021885, R01 GM074068, R01 EB008015]
  4. NATIONAL CANCER INSTITUTE [R03CA126466] Funding Source: NIH RePORTER
  5. NATIONAL CENTER FOR RESEARCH RESOURCES [R01RR021885] Funding Source: NIH RePORTER
  6. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R01EB008015] Funding Source: NIH RePORTER
  7. NATIONAL INSTITUTE OF GENERAL MEDICAL SCIENCES [R01GM074068] Funding Source: NIH RePORTER

向作者/读者索取更多资源

In this paper, we present a segmentation scheme that automatically and accurately segments all the cartilages from magnetic resonance (MR) images of nonpathological knees. Our scheme involves the automatic segmentation of the bones using a three-dimensional active shape model, the extraction of the expected bone-cartilage interface (BCI), and cartilage segmentation from the BCI using a deformable model that utilizes localization, patient specific tissue estimation and a model of the thickness variation. The accuracy of this scheme was experimentally validated using leave one out experiments on a database of fat suppressed spoiled gradient recall MR images. The scheme was compared to three state of the art approaches, tissue classification, a modified semi-automatic watershed algorithm and nonrigid registration (B-spline based free form deformation). Our scheme obtained an average Dice similarity coefficient (DSC) of (0.83, 0.83, 0.85) for the (patellar, tibial, femoral) cartilages, while (0.82, 0.81, 0.86) was obtained with a tissue classifier and (0.73, 0.79, 0.76) was obtained with nonrigid registration. The average DSC obtained for all the cartilages using a semi-automatic watershed algorithm (0.90) was slightly higher than our approach (0.89), however unlike this approach we segment each cartilage as a separate object. The effectiveness of our approach for quantitative analysis was evaluated using volume and thickness measures with a median volume difference error of (5.92, 4.65, 5.69) and absolute Laplacian thickness difference of (0.13, 0.24, 0.12) mm.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据