Compressive behavior of concrete confined by CFRP and transverse spiral reinforcement. Part A: experimental study

期刊

MATERIALS AND STRUCTURES
卷 49, 期 3, 页码 1001-1011

出版社

SPRINGER
DOI: 10.1617/s11527-015-0554-1

关键词

CFRP; Transverse spiral reinforcement; Longitudinal rebar; Experimental study

资金

  1. Natural Science of China [51078132]
  2. China 973 Plan [SQ2011CB076458]
  3. Structure Laboratory of Hunan University

向作者/读者索取更多资源

This study presents the results of an experimental investigation of 18 short concrete columns confined by carbon fiber-reinforced polymer (CFRP) and transverse spiral reinforcement (TSR) under uniaxial compression. Longitudinal rebars are not installed in the specimens in order to eliminate their confinement effect to concrete which affects the analysis of 3-D compression of concrete. The paper only consider for FRP and spiral reinforcement confinement in transverse direction. Two key experimental parameters were investigated: the thickness of the CFRP tube (0.167, 0.334, and 0.501 mm) and the spacing of the TSR (25 and 50 mm). The failure mode, axial and transverse stress-strain relationship, confinement effectiveness, Poisson's ratio and dilatation performance of the specimens were discussed. Test results show that the ultimate strength of concrete has a linear proportional enhancement with an increase in the FRP layer in each TSR category and a decrease in the TSR spacing in each FRP layer category. The ultimate load carrying capacity of the confined concrete depends on the confinement pressure during failure in terms of ultimate strength and axial strain.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据