期刊
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
卷 55, 期 1, 页码 765-775出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIA.2018.2867330
关键词
Harmonic; power quality (PQ); shipboard microgrid; unbalance
资金
- National Science Centre, Poland [DEC-2012/07/E/ST8/01688]
Power quality (PQ) is becoming more and more critical issue in shipboard microgrid systems (SMGs). Especially, the impact of voltage unbalance combined with harmonic distortions on the SMG behavior has not been fully investigated. In this paper, simple PQ assessment models and a series of controlled experiments are proposed and carried out in a real ship under sea-going conditions. The ship experimental results are presented and discussed considering nonlinear bow thruster load and high power ballast pump loads under unbalanced and harmonic voltage conditions. In addition, the analysis of bow thruster current harmonic surges during the ballast pump start-up is presented. Furthermore, the voltage/current distortions of a working generator, bow thruster and pump loads are analyzed. The paper provides a valuable analysis for coping with PQ issues in the SMG.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据