期刊
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
卷 46, 期 4, 页码 1397-1405出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIA.2010.2049811
关键词
AC machine; condition monitoring; demagnetization; diagnostics; inverter; NdFeB magnet; offline testing; permanent magnet (PM); pulsating magnetic field; synchronous motor
Demagnetization of permanent magnets (PMs) used in synchronous motors can occur due to a combination of thermal, electrical, and/or environmental operating stresses. Since PM demagnetization results in degradation of motor performance, efficiency, and reliability, it is important to monitor the quality of PMs regularly. However, there are many limitations to the offline and online methods currently used for magnet quality assessment. In this paper, a new inverter-embedded technique for automated monitoring of magnet quality for permanent-magnet synchronous motors (PMSMs), which overcomes the limitations of existing techniques, is proposed. The main concept is to use the inverter to perform a standstill test whenever the motor is stopped to detect local or uniform PM demagnetization. The machine is excited with a pulsating field at different angular positions, and the change in the current peaks caused by the change in the degree of magnetic saturation due to demagnetization is observed. An experimental study on a 10-hp PMSM verifies that local and uniform PM demagnetizations can be detected with high sensitivity.