4.5 Article

Effect of Humidity on Negative Corona Discharge of Electrostatic Precipitators

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TDEI.2013.6633702

关键词

Peek formula; corona inception electric field; electrostatic precipitators; humidity

资金

  1. Special Funds for Major State Basic Research Projects National 973 Project [2013CB228503]

向作者/读者索取更多资源

The effect of humidity on the negative corona discharge of electrostatic precipitators was experimentally and numerically studied. The current-voltage characteristics of a wire-plate electrostatic precipitator was measured over a range of temperatures and relative humidities. The inception voltage and electric field were determined based on the streamer theory. A numerical method was used to study the influence of humidity on the distributions of electric field and charge density in an electrostatic precipitator. The results showed that the inception voltage and electric field decreased with the increase of humidity. The corona current was significantly affected by the humidity. A modified Peek formula was proposed with a correction to the humidity. The corona currents calculated with the modified Peek formula were in acceptable agreement with the experimental results. The distributions of electric field and charge density were affected by the humidity and applied voltage.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据