期刊
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
卷 61, 期 2, 页码 279-287出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2013.2281595
关键词
Constrained contractions; electromyogram; myoelectric control; powered prostheses; unconstrained contractions
资金
- Natural Sciences and Engineering Research Council of Canada (NSERC) under NSERC [217354-10, A4445-2004]
In this paper, the simultaneous real-time control of multiple degrees of freedom (DOF) for myoelectric systems is investigated. The goal of this study, in which ten able-bodied subjects participated, was to directly compare three control paradigms of constrained (force targeted), unconstrained (position targeted) and resisted unconstrained (position targeted) limb contractions. Artificial neural networks (ANNs) were trained for simultaneous myoelectric control of the three degrees of freedom (DOFs) (wrist flexion-extension, abduction-adduction, and pronation-supination) using mirrored bilateral contractions. In the resisted unconstrained experiment, some resistance to movement was provided using flexible wrist braces in order to increase the required level of muscle activation. The force, in constrained experiments, and position, in unconstrained and resisted unconstrained experiments, were measured. The three protocols were compared off-line using estimation accuracies (R-2) and online using a real-time computer-based target acquisition test. The constrained control paradigm outperformed the unconstrained method in the abduction-adduction DOF (R-constrained(2) = 90.8 +/- 0.6, R-unconstrained(2) = 85.6 +/- 1.6) and pronation-supination DOF (R-constrained(2) = 88.5 +/- 0.9, R-unconstrained(2) = 82.3 +/- 1.6), but no significant difference was found in the flexion-extension DOF. The constrained control method outperformed unconstrained control in two real-time testing metrics including completion time and path efficiency. The constrained method results, however, were not significantly different than those of the resisted unconstrained method (with braces) in both off-line and real-time tests. This suggests that the quality of control using constrained and unconstrained contraction-based myoelectric schemes is not appreciably different when using comparable levels of muscle activation.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据