4.6 Article

CNT/PDMS Composite Flexible Dry Electrodes for Long-Term ECG Monitoring

期刊

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
卷 59, 期 5, 页码 1472-1479

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBME.2012.2190288

关键词

Biocompatible; carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite electrode; ECG electrode; long-term monitoring

资金

  1. Ministry for Health, Welfare & Family Affairs, Korea [A092052]
  2. National Research Foundation of Korea
  3. Ministry of Education, Science and Technology [20110020943]
  4. Ministry of Knowledge Economy [10031779]
  5. Korea Evaluation Institute of Industrial Technology (KEIT) [10031741] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  6. Korea Health Promotion Institute [A092052120002] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  7. National Research Foundation of Korea [2010-0020787] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

We fabricated a carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据