4.7 Article

Nanofiber Web Textile Dry Electrodes for Long-Term Biopotential Recording

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBCAS.2012.2201154

关键词

Biomedical electrodes; contact impedance; nanostructures; textile electrodes

资金

  1. National Research Foundation of Korea (NRF) [R11-2005-065]
  2. Ministry of Knowledge Economy (MKE, Korea) [10033449]
  3. Kyung Hee University [KHU-20110247]
  4. Korea Evaluation Institute of Industrial Technology (KEIT) [10033449] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  5. National Research Foundation of Korea [핵09A3605, 2005-0049405] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Electrode properties are key to the quality of measured biopotential signals. Ubiquitous health care systems require long-term monitoring of biopotential signals from normal volunteers and patients in home or hospital environments. In these settings it is appropriate to use dry textile electrode networks for monitoring purposes, rather than the gel or saline-sponge skin interfaces used with Ag/AgCl electrodes. In this study, we report performance test results of two different electrospun conductive nanofiber webs, and three metal plated fabrics. We evaluated contact impedance, step response, noise and signal fidelity performance indices for all five dry electrodes, and compared them to those of conventional Ag/AgCl electrodes. Overall, we found nanofiber web electrodes matched Ag/AgCl electrode performance more closely than metal plated fabric electrodes, with the contact resistance and capacitance of Ag plated PVDF nanofiber web electrodes being most similar to Ag/AgCl over the 10 Hz to 500 kHz frequency range. We also observed that step responses of all three metal-plated fabrics were poorer than those for nanofiber web electrodes and Ag/AgCl. Further, noise standard deviation and noise power spectral densities were generally lower in nanofiber web electrodes than metal plated fabrics; and waveform fidelity of ECG-like traces recorded from nanofiber web electrodes was higher than for metal plated fabrics. We recommend textile nanofiber web electrodes in applications where flexibility, comfort and durability are required in addition to good electrical characteristics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据