4.4 Article

AC Losses of a Grid-Connected Superconducting Wind Turbine Generator

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TASC.2013.2251252

关键词

AC losses; numerical analysis; superconducting wind turbine generator

向作者/读者索取更多资源

We present a numerical method to estimate the steady-state AC losses of a superconducting wind turbine generator connected to the grid through its AC/DC/AC converter. We use a multiscale simulation with unidirectional couplings between a lumped-parameter wind energy conversion system model, a finite element machine model, and a finite element HTS tape model. The estimation include effects linked to the generator space harmonics, the exciter control, and the AC/DC/AC converter PWM and control. As the superconducting coil is made of several thousand of HTS tapes, we evaluate AC losses for a fraction of them and we interpolate the results to the others. The steady-state AC losses of a 10 MW class generator are estimated to be under 60 W.