4.5 Article

Robust and High Resolution Hyperpolarized Metabolic Imaging of the Rat Heart at 7 T with 3D Spectral-Spatial EPI

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 75, 期 4, 页码 1515-1524

出版社

WILEY
DOI: 10.1002/mrm.25730

关键词

hyperpolarized C-13; metabolic imaging; cardiac imaging; cardiac metabolism; pyruvate; pulse sequences

资金

  1. British Heart Foundation [FS/10/002/28078, FS/14/17/30634, FS/11/50/29038, RG/11/9/28921]
  2. National Institute for Health Research (NIHR) Oxford Biomedical Research Centre Programme
  3. Cancer Research UK [C5255/A12678]
  4. EPSRC [LSI DTC, IT EP/J013250/1]
  5. University of Oxford
  6. John Fell Research Fund
  7. MRC [G0601490] Funding Source: UKRI
  8. British Heart Foundation [FS/10/002/28078, FS/14/17/30634, FS/11/50/29038, RG/11/9/28921] Funding Source: researchfish
  9. Cancer Research UK [16466, 16945] Funding Source: researchfish
  10. Engineering and Physical Sciences Research Council [1104935] Funding Source: researchfish
  11. Medical Research Council [G0601490] Funding Source: researchfish

向作者/读者索取更多资源

Purpose: Hyperpolarized metabolic imaging has the potential to revolutionize the diagnosis and management of diseases where metabolism is dysregulated, such as heart disease. We investigated the feasibility of imaging rodent myocardial metabolism at high resolution at 7 T. Methods: We present here a fly-back spectral-spatial radiofrequency pulse that sidestepped maximum gradient strength requirements and enabled high resolution metabolic imaging of the rodent myocardium. A 3D echo-planar imaging readout followed, with centric ordered z-phase encoding. The cardiac gated sequence was used to image metabolism in rodents whose metabolic state had been manipulated by being fasted, fed, or fed and given the pyruvate dehydrogenase kinase inhibitor dichloroacetate. Results: We imaged hyperpolarized metabolites with a spatial resolution of 2 x 2 x 3: 8 mm(3) and a temporal resolution of 1.8 s in the rat heart at 7 T. Significant differences in myocardial pyruvate dehydrogenase flux were observed between the three groups of animals, concomitant with the known biochemistry. Conclusion: The proposed sequence was able to image in vivo metabolism with excellent spatial resolution in the rat heart. The field of view enabled the simultaneous multi-organ acquisition of metabolic information from the rat, which is of great utility for preclinical research in cardiovascular disease. (C) 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据