4.4 Article

Repetitive Over-Current Characteristics of the Joints Between the YBCO Coated Conductor

期刊

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
卷 19, 期 3, 页码 2419-2422

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TASC.2009.2018201

关键词

Joint; over-current; YBCO coated conductor

资金

  1. Ministry of Science and Technology [R0A-2007000-20063-0]
  2. National Research Foundation of Korea [2007-0056704, 과C6A2001] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

In recent years, the YBCO coated conductor (CC) has been developed as a suitable material for power apparatuses. To fabricate a superconducting apparatus of a large capacity, the joint between the superconducting tapes are inevitable because of the need to have a long length conductor. Consequently, the joint characteristic is very important for the efficiency of the superconducting part in the apparatuses. Besides, maintaining the characteristic of the joint between the superconducting tapes even after repetitive over-current is also important for stability of power apparatuses. Therefore the joints between CC tapes were developed in differing joint length and the characteristics of the joints were compared. In this paper, we present the experimental results of several over-current experiments with the jointed CC tapes. The results of the over-current experiments and the trend of the joint characteristics are compared in point of stability of the joints. Resistance and critical current of the joints were measured from the V - I curve before and after several over-current experiments for observation of the trend of the joint characteristics. This study of repetitive over-current characteristics of the joints may be useful to the development of superconducting apparatuses in forms of magnets.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据