4.7 Article

Compact and Ultrasensitive Temperature Sensor With a Fully Liquid-Filled Photonic Crystal Fiber Mach-Zehnder Interferometer

期刊

IEEE SENSORS JOURNAL
卷 14, 期 1, 页码 167-170

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2013.2279537

关键词

Mach-Zehnder interferometer; photonic crystal fiber; temperature sensor

资金

  1. National Science Foundation of China [61308046, 61275125]
  2. Doctoral Fund of the Ministry of Education of China [20114408120002]
  3. Basic Research program of Shenzhen

向作者/读者索取更多资源

We propose a compact and ultrasensitive all-fiber temperature sensor based on an in-line fully liquid-filled photonic crystal fiber (PCF) Mach-Zehnder interferometer (MZI). It consists of a small piece of index-guiding PCF fully infiltrated by fluid and two standard single-mode fibers offset spliced with PCF. Two core modes LP01 and LP11 are conveniently used as optical arms to form the in-line MZI-type interferometer. Experimental and theoretical investigations of its response to temperature confirm that high temperature sensitivity up to -1.83 nm/degrees C could be realized with such a compact interferometeric PCF temperature sensor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论