4.7 Article

Beat-to-Beat, Reading-to-Reading, and Day-to-Day Blood Pressure Variability in Relation to Organ Damage in Untreated Chinese

期刊

HYPERTENSION
卷 63, 期 4, 页码 790-796

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/HYPERTENSIONAHA.113.02681

关键词

blood pressure monitoring; ambulatory; blood pressure monitoring; home; clinical laboratory science

资金

  1. National Natural Science Foundation of China [30871360, 30871081, 81170245, 81270373]
  2. Ministry of Science and Technology [2011BAI11B04]
  3. Ministry of Education, Beijing, China [NCET-09-0544]
  4. Shanghai Commissions of Science and Technology [11QH1402000]
  5. Shanghai Bureau of Health [XBR2011004]
  6. Shanghai Jiaotong University School of Medicine
  7. Shanghai Commissions of Science and Education [08SG20]

向作者/读者索取更多资源

Whether target organ damage is associated with blood pressure (BP) variability independent of level remains debated. We assessed these associations from 10-minute beat-to-beat, 24-hour ambulatory, and 7-day home BP recordings in 256 untreated subjects referred to a hypertension clinic. BP variability indices were variability independent of the mean, maximum-minimum difference, and average real variability. Effect sizes (standardized ) were computed using multivariable regression models. In beat-to-beat recordings, left ventricular mass index (n=128) was not (P0.18) associated with systolic BP but increased with all 3 systolic variability indices (+2.97-3.53 g/m(2); P<0.04); the urinary albumin-to-creatinine ratio increased (P0.03) with systolic BP (+1.14-1.17 mg/mmol) and maximum-minimum difference (+1.18 mg/mmol); and pulse wave velocity increased with systolic BP (+0.69 m/s; P<0.001). In 24-hour recordings, all 3 indices of organ damage increased (P<0.03) with systolic BP, whereas the associations with BP variability were nonsignificant (P0.15) except for increases in pulse wave velocity (P<0.05) with variability independent of the mean (+0.16 m/s) and maximum-minimum difference (+0.17 m/s). In home recordings, the urinary albumin-to-creatinine ratio (+1.27-1.30 mg/mmol) and pulse wave velocity (+0.36-0.40 m/s) increased (P<0.05) with systolic BP, whereas all associations of target organ damage with the variability indices were nonsignificant (P0.07). In conclusion, while accounting for BP level, associations of target organ damage with BP variability were readily detectable in beat-to-beat recordings, least noticeable in home recordings, with 24-hour ambulatory monitoring being informative only for pulse wave velocity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据