4.7 Article

Novel lead-cobalt composite anodes for copper electrowinning

期刊

HYDROMETALLURGY
卷 137, 期 -, 页码 45-52

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.hydromet.2013.05.004

关键词

Composite anode; Electrowinning; Lead; Cobalt; Titanium

资金

  1. Murdoch University
  2. Minerals and Energy Research Institute of Western Australia
  3. Parker Cooperative Research Centre for Integrated Hydrometallurgy Solutions
  4. AMIRA [P705B]

向作者/读者索取更多资源

PbO2-CoOx and PbO2-Co3O4 composite-coated anodes, using titanium and nickel substrates, have been successfully prepared and tested under typical copper electrowinning conditions. The aim of depositing a well-adhered composite coating onto the surface of the titanium and nickel substrate materials was pursued using three different coatings. The performance of the produced anodes was examined in terms of oxygen evolution potential and service life. Both of the anodes with PbO2-CoOx or PbO2-Co3O4 deposited on titanium resulted in reduction of the oxygen evolution potential of 300 to 400 mV compared with a conventional PbCaSn anode. The anodes prepared by applying the same coatings onto a nickel substrate showed poor stability in the acidic electrolyte media used in this experiment to represent typical copper electrowinning conditions. Of the different coatings tested, a combination of thermal deposition of a SnO2-Sb2O3 interlayer on the surface of a titanium substrate followed by electrodeposition of the top layer of the composite coating resulted in the best electrochemical activity and service life for the anodes. A Tafel slope of 88 mV dec(-1) was recorded for the anode with a top coating of PbO2-CoOx and 47 mV dec(-1) for the anode with a top coating of PbO2-Co3O4, which both compare favourably to the 122 mV dec(-1) which was observed for a conventional PbCaSn anode. Anodisation tests were carried out for a period of 16 h both in the presence and in the absence of the organic additive thiourea in the electrolyte. Corrosion rates were estimated from these tests and the results showed that the titanium-based anode with a SnO2-Sb2O3 interlayer and PbO2-CoOx coating has a lower corrosion rate than a conventional PbCaSn anode, whereas the corrosion rate of the titanium-based anode with same interlayer and PbO2-Co3O4 coating might be much greater but this remains to be confirmed. The results also showed that the addition of thiourea appears to increase the corrosion rate of the composite-coated anodes although it reduces the corrosion rate of a PbCaSn anode. Thiourea showed no obvious effect on the anode potential. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据