4.7 Article

PGD for a complex chromosomal rearrangement by array comparative genomic hybridization

期刊

HUMAN REPRODUCTION
卷 26, 期 4, 页码 941-949

出版社

OXFORD UNIV PRESS
DOI: 10.1093/humrep/der004

关键词

PGD; array; translocation; insertion; complex chromosomal rearrangement

资金

  1. IWT [SBO-60848]
  2. FWO [G.0320.07]
  3. Center of Excellence SymBioSys (Research Council K.U. Leuven) [EF/05/007]
  4. Institute for the Promotion of Innovation through Science and Technology in Flanders (IWT-Vlaanderen

向作者/读者索取更多资源

Patients carrying a chromosomal rearrangement (CR) have an increased risk for chromosomally unbalanced conceptions. Preimplantation genetic diagnosis (PGD) may avoid the transfer of embryos carrying unbalanced rearrangements, therefore increasing the chance of pregnancy. Only 7-12 loci can be screened by fluorescence in situ hybridization whereas microarray technology can detect genome-wide imbalances at the single cell level. We performed PGD for a CR carrier with karyotype 46, XY, ins(3; 2)(p23;q23q14.2), t(6; 14)(p12.2;q13) using array comparative genomic hybridization. Selection of embryos for transfer was only based on copy number status of the chromosomes involved in both rearrangements. In two ICSI-PGD cycles, nine and seven embryos were analysed by array, leaving three and one embryo(s) suitable for transfer, respectively. The sensitivity and specificity of single cell arrays was 100 and 88.8%, respectively. In both cycles a single embryo was transferred, resulting in pregnancy following the second cycle. The embryo giving rise to the pregnancy was normal/balanced for the insertion and translocation but carried a trisomy 8 and nullisomy 9 in one of the two biopsied blastomeres. After 7 weeks of pregnancy the couple miscarried. Genetic analysis following hystero-embryoscopy showed a diploid (90%)/tetraploid (10%) mosaic chorion, while the gestational sac was empty. No chromosome 8 aneuploidy was detected in the chorion, while 8% of the cells carried a monosomy for chromosome 9. In summary, we demonstrate the feasibility and determine the accuracy of single cell array technology to test against transmission of the unbalanced meiotic products that can derive from CRs. Our findings also demonstrate that the genomic constitution of extra-embryonic tissue cannot necessarily be predicted from the copy number status of a single blastomere.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据