4.4 Article

Posterior wall isolation using the cryoballoon in conjunction with pulmonary vein ablation is superior to pulmonary vein isolation alone in patients with persistent atrial fibrillation: A multicenter experience

期刊

HEART RHYTHM
卷 15, 期 8, 页码 1121-1129

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.hrthm.2018.05.014

关键词

Catheter ablation; Cryoablation; Cryoballoon; Persistent atrial fibrillation; Pulmonary vein isolation; Posterior wall isolation

资金

  1. Medtronic

向作者/读者索取更多资源

BACKGROUND Pulmonary vein isolation (PVI) in conjunction with isolation of the posterior left atrial wall (PVI+PWI) is associated with improved clinical outcomes in certain patients with atrial fibrillation (AF). OBJECTIVE The purpose of this multicenter study was to evaluate the acute and long-term outcomes of PVI+PWI vs PVI alone performed using cryoballoon ablation in patients with persistent AF (persAF). METHODS We examined the procedural safety and efficacy and short- and long-term outcomes in 390 consecutive patients with persAF who underwent a first-time cryoballoon ablation procedure using PVI+PWI (n = 222 [56.9%]) vs PVI alone (n = 168 [43.1%]). RESULTS Acute isolation was achieved in 99.7% of all pulmonary veins (PVI+PWI = 99.8% vs PVI alone = 99.3%; P = .23) using 6.3 +/- 1.4 applications and 17 +/- 2 minutes of cryoablation. PWI was achieved using 13.7 +/- 3.2 applications and 34 +/- 10 minutes of cryoablation. Adjunct radiofrequency ablation was required in 1.8% of patients to complete PVI (4 +/- 2 minutes) and in 32.4% to complete PWI (5 +/- 2 minutes). PVI+PWI yielded significantly greater posterior wall (77.2% +/- 6.4% vs 40.6% +/- 4.9%; P < .001) and total left atrial (53.3% +/- 4.2% vs 36.3% +/- 3.8%; P < .001) isolation. In addition, PVI+PWI was associated with greater AF termination (19.8% vs 8.9%; P = .003) and conversion to atrial flutters (12.2% vs 5.4%; P = .02). Adverse events were similar in both groups, whereas recurrence of AF and all atrial arrhythmias was lower with PVI+PWI at 12 months of follow-up. Moreover, in a Cox regression analysis, PVI+PWI emerged as a significant predictor of freedom from recurrent atrial arrhythmias (hazard ratio: 2.04; 95% confidence interval: 1.15-3.61; P = .015). CONCLUSION PVI+PWI can be achieved safely and effectively using the cryoballoon. This approach appears superior to PVI alone in patients with persAF.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据