BACKGROUND Most atrial fibrillation (AF) ablation studies have consisted predominantly of males; accordingly, there is a paucity of information on the safety and efficacy of catheter ablation in a large cohort of female AF patients. OBJECTIVE The purpose of this study was to evaluate catheter ablation for AF in female patients. METHODS From January 2005 to May 2008, 3265 females underwent pulmonary vein antrum isolation. Success rates, patient profiles, and complications were collected. RESULTS Approximately 16% of our population was female (P < .001). Females were older (59 +/- 13 vs. 56 +/- 19 years; P < .01) and had a lower prevalence of paroxysmal atrial fibrillation (PAF; 46% vs. 55%; P < .001). Females failed more antiarrhythmics (4 +/- 1 vs. 2 +/- 3; P = .04) and were referred later for catheter ablation (6.51 +/- 7 vs. 4.85 +/- 6.5 years; P = .02) than males. More females failed ablation (31.5% vs. 22.5%; P = .001) and had nonantral sites of firing than males (P < .001). Female patients had 11 (2.1%) hematomas versus 27 (0.9%) in males. CONCLUSIONS Five times as many males underwent catheter ablation than females. Females failed more ablations possibly because of a higher prevalence of nonantral firing, non-PAF, and longer history of AF. Females had more bleeding complications than males.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据