4.4 Article

Microvolt T-wave alternans and electrophysiologic testing predict distinct arrhythmia substrates: Implications for identifying patients at risk for sudden cardiac death

期刊

HEART RHYTHM
卷 7, 期 6, 页码 763-768

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.hrthm.2010.02.012

关键词

Electrophysiologic study; Microvolt T-wave alternans; Sudden cardiac death; Ventricular fibrillation; Ventricular tachycardia

向作者/读者索取更多资源

BACKGROUND Better risk stratification of patients receiving an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death (SCD) is needed. Although microvolt T-wave alternans (MTWA) and electrophysiologic study (EPS) are independent markers for SCD, the Alternans Before Cardioverter Defibrillator (ABCD) trial found the combination to be more predictive than either test alone. OBJECTIVE The purpose of this study was to test the hypothesis that EPS and MTWA measure different elements of the arrhythmogenic substrate and, therefore, predict distinct arrhythmia outcomes. METHODS The ABCD trial enrolled 566 patients with ischemic cardiomyopathy, left ventricular ejection fraction (LVEF) <= 0.40, and nonsustained ventricular tachycardia. All patients underwent both MTWA test and EPS. The performance of MTWA and EPS in predicting stable ventricular tachyarrhythmic events (S-VTEs) versus unstable ventricular tachyarrhythmic events (U-VTEs), defined as either polymorphic ventricular tachycardia or ventricular fibrillation, was analyzed using Kaplan-Meier event rates and the log rank test. RESULTS MTWA and EPS were abnormal in 71% and 39% of patients, respectively. There were 28 S-VTEs and 10 U-VTEs. MTWA was predictive of U-VTEs (event rate 2.7% in abnormals vs 0% in normals, P = .04), whereas EPS was not (1.5% vs 3.2%, P = .55). In contrast, EPS predicted S-VTEs (9.7% vs 2.2%, P < .01), but MTWA did not (5.5% vs 4.4%, P = .57). Whereas the extent of left ventricular contractile dysfunction alone (LVEF <= 0.30 vs LVEF 0.31-0.40) did not predict events, MTWA predicted events better than did EPS in subjects with LVEF <= 0.30. In contrast, EPS predicted events better than did MTWA test in subjects with LVEF >0.30. CONCLUSION The study data suggest that EPS and MTWA identify distinct arrhythmogenic substrates and, when used in combination, may better predict the complex electroanatomic substrates that underlie the risk for SCD.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据