A wireless bio-sensing microfluidic chip based on resonating 'μ-divers'

期刊

LAB ON A CHIP
卷 15, 期 10, 页码 2318-2326

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c5lc00361j

关键词

-

资金

  1. NSF of China [51405480, 91323304, 61234007, 61321492]
  2. Chinese 973 Project [2011CB309503]
  3. National Key Technology RD Program [2012BAK08B05]
  4. Science and Technology Commission of Shanghai Municipality [11391901900]

向作者/读者索取更多资源

A magneto-elastic resonant 'micro-diver' system (MER-mu DS) is proposed and developed for rapid liquid-phase detection of pathogens in a wireless way. The magneto-elastic micro-resonator (i. e., the mu-diver) is placed in the micro-chamber of the MER-mu DS that is connected to the inlet/outlet for flow of the liquid analyte and a closed-loop micro-channel. After specific attachment of the analyte onto the mu-diver, the mu-diver is conveyed by the flow into the detection segment of the channel, around which a metal micro-coil is wound for both excitation resonance of the mu-diver and reading of its resonance frequency signal. After the pre-functionalized mu-diver captures the analyte and, then, is driven into the detection channel segment, the added mass induced resonant frequency shift can be wirelessly sensed by the coil. The micro-system features rapid and repeatable liquid-phase bio-sensing and the wireless signal readout scheme is favorable to real-time pathogen detection in liquid food, e. g., milk or juice, for food safety applications. An equivalent circuit model is established for design of the magneto-elastic mu-diver. After a bar-shaped mu-diver with length-extensional bulk-resonance mode is optimally designed and micro-fabricated, the MER-mu DS is formed by micro-machining/assembling techniques. By placing a biotin-immobilized mu-diver into the wireless micro-sensing system, avidin-attached magnetic beads are detected to calibrate the mass sensitivity as 0.061 Hz pg(-1), which well confirms the modeling result. By using the antibody-immobilized mu-diver, PBS solution with an E. coli concentration of 10(2)-10(8) CFU mL(-1) is detected, resulting in a corresponding wireless f(0)-shift sensing signal of about 300-2300 Hz and a limit of detection of 102 CFU mL(-1). Food safety application potential of the MER-mu DS technique is proven by detection of E. coli added to orange and apple juices (E. coli concentration: 10(4)-10(8) CFU mL(-1)).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据