4.8 Article

Factors determining the quality of screening colonoscopy: a prospective study on adenoma detection rates, from 12 134 examinations (Berlin colonoscopy project 3, BECOP-3)

Journal

GUT
Volume 62, Issue 2, Pages 236-241

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/gutjnl-2011-300167

Keywords

-

Funding

  1. Deutsche Krebshilfe e.V. [108166]
  2. Olympus
  3. Pentax
  4. Falk Companies

Ask authors/readers for more resources

Background Screening colonoscopy (SC) outcome quality is best determined by the adenoma detection rate (ADR). The substantial variability in the ADRs between endoscopists may reflect different skills, experience and/or equipment. Objective To analyse the potential factors that may influence ADR variance, including case volume. Design 12 134 consecutive SCs (mean age 64.5 years, 47% men) from 21 Berlin private-practice colonoscopists were prospectively studied during 18 months. The data were analysed using a two-level mixed linear model to adequately address the characteristics of patients and colonoscopists. The ADR was regressed after considering the following factors: sex, age, bowel cleanliness, NSAID intake, annual SC case volume, lifetime experience, instrument withdrawal times, instrument generations used, and the number of annual continuing medical education (CME) meetings attended by the physician. The case volume was also retrospectively analysed from the 2007 national SC registry data (312 903 colonoscopies and 1004 colonoscopists). Results The patient factors that correlated with the ADR were sex, age (p<0.001) and low quality of bowel preparation (p=0.005). The factors that were related to the colonoscopists were the number of CME meetings attended (p=0.012) and instrument generation (p=0.001); these factors accounted for approximately 40% of the interphysician variability. Within a narrow range (6-11 min), the withdrawal time was not correlated with the ADR. Annual screening case volume did not correlate with the ADR, and this finding was confirmed by the German registry data. Conclusions The outcome quality of screening colonoscopies is mainly influenced by individual colonoscopist factors (ie, CME activities) and instrument quality.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available