Journal
GEOTECHNIQUE
Volume 61, Issue 7, Pages 613-620Publisher
ICE PUBL
DOI: 10.1680/geot.9.P.086
Keywords
footings/foundations; ground improvement; model tests; reinforced soils; settlement; soil/structure interaction
Categories
Funding
- Kingdom of Brunei, Darussalam
Ask authors/readers for more resources
The mechanism whereby foundation loading is transmitted through the column has received little attention from researchers. This paper reports on some interesting findings obtained from a laboratory-based model study in respect of this issue. The model tests were carried out on samples of soft clay, 300 mm in diameter and 400 mm high. The samples were reinforced with fully penetrating stone columns, of three different diameters, made of crushed basalt. Four pressure cells were located along each stone column. The 60 mm diameter footing used in the model was supported on a clay bed reinforced with a stone column and subjected to foundation loading under drained conditions. The results show that the dissipation of excess pore water pressure developed during the initial application of total stresses, when the foundation was subjected to no loading, generated considerable stresses within the column, and that this was directly attributable to the development of negative skin friction. The pressure distributions in the column during foundation loading showed some complex behaviour.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews