4.7 Article

High resolution ambulatory holter ECG events detection-delineation via modified multi-lead wavelet-based features analysis: Detection and quantification of heart rate turbulence

Journal

EXPERT SYSTEMS WITH APPLICATIONS
Volume 38, Issue 5, Pages 5299-5310

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.eswa.2010.10.028

Keywords

ECG Delineation; Discrete wavelet transform; Multi lead analysis; Curve Length Method; Premature ventricular contraction; Heart rate turbulence; Binary Neyman-Pearson radius test

Ask authors/readers for more resources

The presented study describes a false-alarm probability-FAP bounded solution for detecting and quantifying Heart Rate Turbulence (HRT) major parameters including heart rate (HR) acceleration/deceleration, turbulence jump, compensatory pause value and HR recovery rate. To this end, first, high resolution multi-lead holter electrocardiogram (ECG) signal is appropriately pre-processed via Discrete Wavelet Transform (DWT) and then, a fixed sample size sliding window is moved on the pre-processed trend. In each slid, the area under the excerpted segment is multiplied by its curve-length to generate the Area Curve Length (ACL) metric to be used as the ECG events detection-delineation decision statistic (DS). The ECG events detection-delineation algorithm was applied to various existing databases and as a result, the average values of sensitivity and positive predictivity Se = 99.95% and P+ = 99.92% were obtained for the detection of QRS complexes, with the average maximum delineation error of 7.4 msec, 4.2 msec and 8.3 msec for P-wave. QRS complex and T-wave, respectively. Because the heart-rate time series might include fast fluctuations which don't follow a premature ventricular contraction (PVC) causing high-level false alarm probability (false positive detections) of HRT detection, based on the binary two-dimensional Neyman-Pearson radius test (which is a FAP-bounded classifier), a new method for discrimination of PVCs from other beats using the geometrical-based features is proposed. The statistical performance of the proposed HRT detection-quantification algorithm was obtained as Se = 99.94% and P+ = 99.85% showing marginal improvement for the detection-quantification of this phenomenon. In summary, marginal performance improvement of ECG events detection-delineation process, high performance PVC detection and isolation from noisy holter data and reliable robustness against holter strong noise and artifacts can be mentioned as important merits and capabilities of the proposed HRT detection algorithm. (C) 2010 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available