4.7 Article

Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction

Journal

EUROPEAN RADIOLOGY
Volume 23, Issue 11, Pages 2927-2933

Publisher

SPRINGER
DOI: 10.1007/s00330-013-2920-0

Keywords

Coronary computed tomography angiography; High-pitch spiral acquisition; Iterative reconstruction; Accuracy; Radiation dose

Funding

  1. Ministry of Science and Technology of China [2007BAI05B02]
  2. Bayer Healthcare, Berlin, Germany
  3. Bayer Healthcare
  4. Bracco
  5. GE Healthcare
  6. Siemens

Ask authors/readers for more resources

To evaluate the diagnostic accuracy of sub-milliSievert (mSv) coronary CT angiography (cCTA) using prospectively ECG-triggered high-pitch spiral CT acquisition combined with iterative image reconstruction. Forty consecutive patients (52.9 +/- 8.7 years; 30 men) underwent dual-source cCTA using prospectively ECG-triggered high-pitch spiral acquisition. The tube current-time product was set to 50 % of standard-of-care CT examinations. Images were reconstructed with sinogram-affirmed iterative reconstruction. Image quality was scored and diagnostic performance for detection of a parts per thousand yen50 % stenosis was determined with catheter coronary angiography (CCA) as the reference standard. CT was successfully performed in all 40 patients. Of the 601 assessable coronary segments, 543 (90.3 %) had diagnostic image quality. Per-patient sensitivity for detection of a parts per thousand yen50 % stenosis was 95.7 % [95 % confidence interval (CI), 76.0-99.8 %] and specificity was 94.1 % (95 % CI, 69.2-99.7 %). Per-vessel sensitivity was 89.5 % (95 % CI, 77.8-95.6 %) with 93.2 % specificity (95 % CI, 86.0-97.0 %). The area under the receiver-operating characteristic curve on per-patient and per-vessel levels was 0.949 and 0.913. Mean effective dose was 0.58 +/- 0.17 mSv. Mean size-specific dose estimate was 3.14 +/- 1.15 mGy. High-pitch prospectively ECG-triggered cCTA combined with iterative image reconstruction provides high diagnostic accuracy with a radiation dose below 1 mSv for detection of coronary artery stenosis. aEuro cent Cardiac CT with sub-milliSievert radiation dose is feasible in many patients aEuro cent High-pitch spiral CT acquisition with iterative reconstruction detects coronary stenosis accurately. aEuro cent Iterative reconstruction increases who can benefit from low-radiation cardiac CT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available