Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device

Journal

EUROPEAN RADIOLOGY
Volume 22, Issue 4, Pages 765-771

Publisher

SPRINGER
DOI: 10.1007/s00330-011-2308-y

Keywords

Three-dimensional; Lower extremity; Measure; Children; Adolescent

Funding

  1. National Council for Scientific and Technological Development (CNPq) of Brazil

Ask authors/readers for more resources

To evaluate three-dimensional (3D) measurements of the lower extremity using a biplanar low-dose X-ray device in children and adolescents. Firstly, 3D measurements of eight dried bones were analysed by a biplanar low-dose X-ray device (LDX) using stereoscopic software and compared with 3D computed tomography (CT). Secondly, 47 lower limbs of children and adolescents were studied using LDX two-dimensional (2D) and 3D measurements. Both parts were evaluated for femoral and tibial lengths and mechanical angles, frontal and lateral knee angulations, and the femoral neck-shaft angle. The 3D specimen comparison between LDX and CT measurements showed no significant differences: femoral length (P = 0.069), tibial length (P = 0.059), femoral mechanical angle (P = 0.475), tibial mechanical angle (P = 0.067), frontal knee angulation (P = 0.198), lateral knee angulation (P = 0.646) and femoral neck-shaft angle (P = 0.068). The comparison between LDX 2D and 3D measurements showed significant differences in tibial length (P = 0.003), femoral mechanical angle (P < 0.001) and femoral neck-shaft angle (P = 0.001); other parameters were unremarkable. The 3D LDX system presented reliable measurements compared with 3D CT. Differences between LDX 2D and 3D measurements were noted in the femoral mechanical angle, femoral neck-shaft angle and tibial length. Moderate to good interobserver agreement for the 3D LDX measurements were found. aEuro cent Low radiation dose is essential when assessing potential lower extremity discrepancies aEuro cent A new biplanar low-dose X-ray device can assess such discrepancies in children/adolescents aEuro cent This LDX device provides equally reliable 3D measurements as prevalent practice LDX measurements carry good overall interobserver agreement.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available