4.5 Article

The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength

Journal

EUROPEAN JOURNAL OF RADIOLOGY
Volume 82, Issue 2, Pages 296-301

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2012.11.012

Keywords

Cardiovascular magnetic resonance imaging; Myocardial feature tracking; Strain; Quantification

Funding

  1. Philips Healthcare
  2. Bayer Schering Pharma
  3. British Heart Foundation (BHF) [RE/08/003, FS/10/029/28253]
  4. Biomedical Research Centre [BRC-CTF 196]
  5. American College of Cardiology Foundation
  6. Edna Ittner Pediatric Foundation
  7. Children's Hospital and Medical Center Foundation
  8. Wellcome Trust
  9. Engineering and Physical Sciences Research Council (EPSRC) [WT 088641/Z/09/Z]
  10. National Institute for Health Research (NIHR) via the comprehensive BRC award
  11. British Heart Foundation [FS/11/43/28760, FS/10/029/28253] Funding Source: researchfish

Ask authors/readers for more resources

Background: Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images. We sought to determine whether magnetic field strength affects the intra-observer reproducibility of CMR-FT strain analysis. Methods: We studied 2 groups, each consisting of 10 healthy subjects, at 1.5 T or 3 T Analysis was performed at baseline and after 4 weeks using dedicated CMR-FT prototype software (Tomtec, Germany) to analyze standard SSFP cine images. Right ventricular (RV) and left ventricular (LV) longitudinal strain (Ell(RV) and Ell(LV)) and LV long-axis radial strain (Err(LAX)) were derived from the 4-chamber cine, and LV shor-taxis circumferential and radial strains (Ecc(SAX), Err(SAX)) from the short-axis orientation. Strain parameters were assessed together with LV ejection fraction (EF) and volumes. Intra-observer reproducibility was determined by comparing the first and the second analysis in both groups. Results: In all volunteers resting strain parameters were successfully derived from the SSFP images. There was no difference in strain parameters, volumes and EF between field strengths (p > 0.05). In general EccSAX was the most reproducible strain parameter as determined by the coefficient of variation (CV) at 1.5 T (CV 13.3% and 46% global and segmental respectively) and 3 T (CV 17.2% and 31.1% global and segmental respectively). The least reproducible parameter was EllRV (CV 1.5 T 28.7% and 53.2%; 3 T 43.5% and 63.3% global and segmental respectively). Conclusions: CMR-FT results are similar with reasonable intra-observer reproducibility in different groups of volunteers at 1.5 T and 3 T. CMR-FT is a promising novel technique and our data indicate that results might be transferable between field strengths. However there is a considerable amount of segmental variability indicating that further refinements are needed before CMR-FT can be fully established in clinical routine for quantitative assessment of wall mechanics and strain. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available