Measurement of renal volume using respiratory-gated MRI in subjects without known kidney disease: Intraobserver, interobserver, and interstudy reproducibility

Journal

EUROPEAN JOURNAL OF RADIOLOGY
Volume 80, Issue 3, Pages E212-E216

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2010.09.005

Keywords

Intraobserver, interobserver, and interstudy reproducibility; Magnetic resonance imaging; Renal volume; Smallest detectable difference

Ask authors/readers for more resources

Objective: Since renal volume is to be considered in managing renal diseases, a reproducible technique is needed. Our aim was to estimate intraobserver, interobserver, and interstudy reproducibility of renal volume measurement in subjects without known kidney disease using magnetic resonance (MR) imaging. Materials and methods: We studied 20 patients (age range 33-82 years) without known renal disease using 1.5-T MR imaging with a respiratory-gated two-dimensional coronal balanced steady state free precession sequence. Each patient repeated the study after 1 h. Two readers independently segmented the area of both kidneys of the first study, subtracting cysts. After 1 week, the first reader segmented the second study and repeated the segmentation of the first study. The volume of each kidney was obtained by multiplying the renal area on each slice by the slice thickness and summing all the partial volumes. Reproducibility was assessed by Bland-Altman and Wilcoxon statistics. The coefficient of repeatability (CoR) was summed to the absolute value of bias; the ratio between this sum and the mean of the two data sets was used as a measure of variability while its complement to 100% was used as a measure of reproducibility. Results: Acquisition time was 2-3 min. Segmentation time was 20-25 min. Intraobserver variability results in a CoR of 7 ml and in a reproducibility of 95%, interobserver variability 8.8-9.8 ml and 87-88%, interstudy variability 9.8-10.6 ml and 91-93%, respectively. Considering both the effect of observer and the repetition of the study, the reproducibility was 83-87%. Conclusion: Renal volume measurement by MR imaging is highly reproducible. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available