4.5 Article

Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms

Journal

EUROPEAN JOURNAL OF RADIOLOGY
Volume 65, Issue 2, Pages 228-234

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2007.03.034

Keywords

lung; emphysema; computed tomography; emphysema detection software; reconstruction algorithm; pulmonary function tests

Ask authors/readers for more resources

Purpose: The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods: Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorithm employed to reconstruct the raw data, no additional radiation was required. CT data were analysed using self-written emphysema detection and quantification software providing lung volume, emphysema volume (EV), emphysema index (EI) and mean lung density (MLD). Results: The use of kernels with BHC led to a significant decrease in MLD (5%) and EI (61-79%) in comparison with kernels without BHC. The absolute difference (from smooth soft tissue kernel) in MLD ranged from -0.6 to -6.1 HU and were significant different for all kernels. The EV showed absolute differences between -0.05 and -0.4 L and was significantly different for all kernels. The EI showed absolute differences between -0.8 and -5.1 and was significantly different for all kernels. Conclusion: The use of kernels with BHC led to a significant decrease in MLD and EI. The absolute differences between different kernels without BHC were small but they were larger than the known interscan variation in patients. Thus, for follow-up examinations the same reconstruction algorithm has to be used and use of BHC has to be avoided. (C) 2007 Elsevier Ireland Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available