Monochromatic beam characterization for Auger electron dosimetry and radiotherapy

Journal

EUROPEAN JOURNAL OF RADIOLOGY
Volume 68, Issue 3, Pages S137-S141

Publisher

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2008.04.050

Keywords

Auger electron radiotherapy; Photon activation therapy; K-edge Capture; Monochromatic X-rays; Beam characterization

Ask authors/readers for more resources

Dosimetry for Auger electron radiotherapy using monochromatic photon beams requires knowledge of beam characteristics. This study characterized a 35-keV photon beam generated at the LSU/CAMD synchrotron. Beam energy was measured by Compton spectroscopy and Si640c powder diffraction. Photon spatial distribution and virtual source position were measured using radiochromic film. Central-axis fluence was determined from Compton scattering measurements and application of the Klein-Nishina cross-section with percent polarization fit to results at 2-4 scattering angles. Broad-beam fluence was combined with MCNP5 Monte Carlo dose per fluence calculations to generate dose versus depth in a polymethylmethacrylate phantom, which was compared to ionization chamber and radiochromic film depth-dose measurements. For 22-41 keV beams, diffraction-based and Compton-based energy measurements agreed to within -0.1 +/- 0.3 and 0.6 +/- 0.3 keV, respectively, of monochromator calibrated energies. At 35 keV and 0.66 cm depth, dose uniformity over 80% of the 2.8 cm x 2.5 cm beam varied from 105 to 78% of the central-axis value horizontally and from 90 to 100% vertically. Narrow-beam divergence yielded vertical and horizontal virtual source-to-surface distances of 3.8 +/- 0.2 and 15.7 +/- 1.0 m, respectively. Incident fluence rates for a 35-keV beam (100 mA ring current) ranged from 1.181 +/- 0.011 x 10(11) to 3.053 +/- 0.004 x 10(11) photons cm(-2) s(-1) with; 100% polarization in the horizontal plane. Ion chamber and film dose measurements underestimated MCNP5-based dose by an average of 6.4 +/- 0.8 and 9.1 +/- 0.8%, respectively, over measured depths. These practical beam characterization methods should allow subsequent Monte Carlo dose calculations needed for planning future radiotherapy studies. Although simulated and measured depth-dose curves agree well in shape, improvement in absolute dose is desirable. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available