4.6 Article

Temporary percutaneous right ventricular support using a centrifugal pump in patients with postoperative acute refractory right ventricular failure after left ventricular assist device implantation

Journal

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
Volume 41, Issue 1, Pages 219-223

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1016/j.ejcts.2011.04.029

Keywords

Right heart failure; Temporary circulatory assistance; RVAD

Ask authors/readers for more resources

OBJECTIVE: Acute right ventricular (RV) failure is a life-threatening condition with a poor prognosis, and sometimes the use of mechanical circulatory support is inevitable. In this article, we describe our experience using a centrifugal pump as a temporary percutaneous right ventricular assist device (RVAD) in patients with postoperative acute refractory RV failure after left ventricular assist device (LVAD) implantation. METHODS: We retrospectively reviewed eight consecutive patients with acute RV failure who underwent temporary percutaneous RVAD implantation using a centrifugal pump after LVAD implantation between April 2008 and February 2011. A Dacron graft was attached to the main pulmonary artery and passed through a subxiphoid exit, where the outflow cannula was inserted. The inflow cannula was percutaneously cannulated using Seldinger's technique in the femoral vein. The chest was definitely closed. The technique allowed bedside removal, avoiding chest re-opening. RESULTS: The median patient age was 52 years (range: 41-58). The median duration of support was 14 days (range: 12-14). RV systolic function improved; central venous pressure and mean pulmonary artery pressure decreased significantly after RVAD support. In three patients, an oxygenator was integrated into the RVAD due to impaired pulmonary function. Six patients were successfully weaned. Five patients survived to hospital discharge. Technical problems or serious complications concerning decannulation were not observed. CONCLUSION: This report suggests that implantation of temporary percutaneous RVAD using a centrifugal pump is a safe alternative in the treatment of postoperative acute refractory RV failure. Ease of device implantation, weaning, explantation, and limited number of complications justify a liberal use.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available