4.6 Article

Postoperative chest tube management: measuring air leak using an electronic device decreases variability in the clinical practice

Journal

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
Volume 35, Issue 1, Pages 28-31

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1016/j.ejcts.2008.09.005

Keywords

Variations in clinical practice; Lung resection; Chest drainage

Ask authors/readers for more resources

Objectives: Since there are no data in the literature regarding variability in the management of postoperative pleural. drainages, we have designed a prospective randomized study aimed at measuring inter-observer variability in deciding when to withdraw chest tubes after lung resection and to evaluate if the use of an electronic device to measure postoperative air teak decreases clinical practice variations. Methods: Sixty-one patients undergoing pulmonary resection were randomly assigned to one of the following groups: digital group (electronic measure of pleural. air teak using Milticore AB DigiVent (TM) chest drainage system) or traditional group (standard water seat pleural chamber). Chest tube withdrawal criteria were established in advance. During morning rounds, two thoracic surgeons with comparable clinical experience and blinded to the decision of their counterpart, evaluated chest tube withdrawal criteria and noted whether the tube should be withdrawn or not. Inter-observer variability kappa index and global, positive, and negative agreement rates were calculated on 2 x 2 tables. Each observation episode was considered in the calculation. Results: Fifty-four observations were recorded in the traditional group. Kappa coefficient was 0.37 (overall agreement rate: 0.58; positive agreement rate: 0.72; and negative agreement rate: 0.64). In the digital group, 67 observations were recorded. Kappa coefficient was 0.88 (overall agreement rate: 0.94; positive agreement rate 0.94; and negative agreement rate 0.94). Conclusions: We have demonstrated a high rate of disagreement related to the indication to remove chest tubes after lung resection and the improvement of the agreement rate with the use of an electronic device to measure postoperative air teak and pleural pressures. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available