4.4 Article

A randomised trial of the analgesic efficacy of ultrasound-guided transversus abdominis plane block after caesarean delivery under general anaesthesia

Journal

EUROPEAN JOURNAL OF ANAESTHESIOLOGY
Volume 29, Issue 2, Pages 88-94

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/EJA.0b013e32834f015f

Keywords

anaesthetic technique; caesarean delivery; general anaesthesia; morphine consumption; transversus abdominis plane block; ultrasound

Categories

Funding

  1. KK Women's and Children's Hospital Research Committee [RAU/2009/154]

Ask authors/readers for more resources

Context Previous studies examining the efficacy of transversus abdominis plane block after caesarean section have mostly been in parturients under spinal anaesthesia. Objectives We postulated that the advantage of performing transversus abdominis plane block after caesarean section might be even more obvious after general anaesthesia, resulting in reduced 24-h consumption of morphine. Design, setting, patients and interventions In this single centre, randomised double-blind controlled trial, 40 women who underwent caesarean delivery under general anaesthesia were allocated randomly to receive a transversus abdominis plane block or no block. In those who received the block, 20ml of levobupivacaine 2.5 mg ml(-1) was deposited bilaterally into the transversus abdominis plane under ultrasound guidance using a Sonosite Titan (SonoSite, Bothell, Washington, USA) 7-13 MHz linear transducer at the end of surgery when the patient was still anaesthetised. Main outcome measures We recorded patient-controlled intravenous morphine use for 24 h, pain scores at rest and activity, sedation, nausea and vomiting, use of antiemetic medication and overall maternal satisfaction. The primary outcome was 24-h morphine consumption. Results Patients who received the transversus abdominis plane block used significantly less morphine in 24 h than those in the control group [12.3 (2.6) vs. 31.4 mg (3.1), P<0.001) and had higher satisfaction scores [16 (80%) vs. 5 (25%), P=0.012). There were no differences between groups in the visual analogue pain scores, sedation level, nausea and vomiting or the use of antiemetic medication. Conclusion Ultrasound-guided transversus abdominis plane block reduced morphine consumption following caesarean section under general anaesthesia, with increased maternal satisfaction. Eur J Anaesthesiol 2012; 29:88-94 Published online 19 December 2011

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available