4.7 Article

Early diagnosis of acute myocardial infarction in the elderly using more sensitive cardiac troponin assays

Journal

EUROPEAN HEART JOURNAL
Volume 32, Issue 11, Pages 1379-1389

Publisher

OXFORD UNIV PRESS
DOI: 10.1093/eurheartj/ehr033

Keywords

Acute coronary syndromes; Myocardial infarction; New biomarkers; Troponin; Coronary; Artery disease; Elderly; Prognosis

Funding

  1. Swiss National Science Foundation [PP00B-102853]
  2. Swiss Heart Foundation
  3. Abbott
  4. Roche
  5. Siemens
  6. Department of Internal Medicine, University Hospital Basel
  7. Novartis Foundation
  8. Krokus Foundation
  9. Astra Zeneca
  10. Biosite
  11. Brahms
  12. Nanosphere

Ask authors/readers for more resources

Aims To examine the diagnostic accuracy of sensitive cardiac troponin (cTn) assays in elderly patients, since elevated levels with sensitive cTn assays were reported in 20% of elderly patients without acute myocardial infarction (AMI). Methods and results In this multi-centre study, we included 1098 consecutive patients presenting with symptoms suggestive of AMI, 406 (37%) were >70 years old. Measurement of three investigational sensitive cTn assays [ Roche high-sensitive cTnT (hs-cTnT), Siemens cTnI-Ultra, and Abbott-Architect cTnI) and the standard assay (Roche cTnT) was performed in a blinded fashion. The final diagnosis was adjudicated by two independent cardiologists. Acute myocardial infarction was the adjudicated final diagnosis in 24% of elderly patients. Among elderly patients without AMI, baseline cTn levels were elevated above the 99th percentile in 51% with Roche hs-cTnT, in 17% with Siemens TnI-Ultra, and 13% with Abbott-Architect cTnI. The diagnostic accuracy as quantified by the area under the receiver operating characteristic (ROC) curve (AUC) was significantly greater for the sensitive cTn assays compared with the standard assay (AUC for Roche hs-cTnT, 0.94; Siemens cTnI-Ultra, 0.95; and Abbott-Architect cTnI, 0.95 vs. AUC for the standard assay, 0.90; P < 0.05 for comparisons). The best cut-offs for the sensitive cTn-assays determined by the ROC-curve in elderly patients differed clearly from those in younger patients. Furthermore, the prognostic value regarding 90-day mortality varied among the sensitive cTn assays. Conclusion Sensitive cTn assays have high diagnostic accuracy also in the elderly. Mild elevations are common in elderly non-AMI patients, therefore the optimal cut-off levels are substantially higher in elderly as compared with younger patients. Furthermore, sensitive cTn assays yielded different prognostic value (ClinicalTrials. gov number, NCT00470587).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available