4.3 Article

A disposable electrochemical sensor based on bifunctional periodic mesoporous organosilica for the determination of lead in drinking waters

Journal

JOURNAL OF SOLID STATE ELECTROCHEMISTRY
Volume 19, Issue 7, Pages 2117-2127

Publisher

SPRINGER
DOI: 10.1007/s10008-015-2889-5

Keywords

Bifunctional periodic mesoporous organosilica; Disulfide- and tetrasulfide-bridged; Modified carbon paste electrode; Voltammetric analysis; Lead; Drinking waters

Funding

  1. CAM - European FEDER Program [S2013/ABI-3028]

Ask authors/readers for more resources

A new bifunctional disulfide-and tetrasulfide-bridged periodic mesoporous organosilica (PMO) with mercaptothiazoline ligand was synthesized and employed to prepare chemically modified carbon paste electrodes for Pb(II) detection in aqueous media by square wave adsorptive stripping voltammetry. To demonstrate the real interest of bifunctionalization, carbon paste electrodes were prepared with disulfide-and tetrasulfide-bridged PMO without mercaptothiazoline ligand. Results showed the importance of bifunctionalization of PMOs to improve the sensitivity for the determination of Pb(II) in water samples. To achieve the most accurate and sensitive Pb(II) measurements, optimization of the operating parameters in preconcentration and detection steps was performed. Finally, the modified carbon paste electrode prepared with bifunctional disulfide-bridged PMO with mercaptothiazoline ligand was applied to determine Pb(II) in different water samples without any pretreatment. Using this electrode, the optimal operating conditions were 120 s of electrolysis time in HCl 0.4 M. In these conditions, the voltammetric signal increased linearly with the preconcentration time from 1 to 10 min. Under optimized conditions, the linear range was 2-100 mu g/ L (R-2= 0.9943) with a detection limit of 0.5 mu g/L (for 5-min preconcentration time). Good reproducibility was achieved on both single and equally prepared electrodes. The accuracy of the method was validated by analysing Pb(II) in different drinking and natural water samples, with spiked recoveries in the range of 95-105 +/- 10 %. The results demonstrated that the prepared electrochemical sensor exhibited selectivity, fast response time and exceptional long-time stability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available