4.8 Article

Comparisons of Ultrafine and Fine Particles in Their Associations with Biomarkers Reflecting Physiological Pathways

Journal

ENVIRONMENTAL SCIENCE & TECHNOLOGY
Volume 48, Issue 9, Pages 5264-5273

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/es5006016

Keywords

-

Funding

  1. NIEHS [1R01 ES0158640, P30 ES05022, 5P30ES007048]
  2. Health Effects Institute [4760-RPFA05-3]
  3. Beijing Environmental Protection Agency [OITC-G08026056]

Ask authors/readers for more resources

Using a quasi-experimental opportunity offered by greatly restricted air pollution emissions during the Beijing Olympics compared to before and after the Olympics, we conducted the current study to compare ultrafine particles (UFPs) and fine particles (PM2.5) in their associations with biomarkers reflecting multiple pathophysiological pathways linking exposure and cardiorespiratory events. Number concentrations of particles (13.0-764.7 nm) and mass concentrations of PM2.5 were measured at two locations within 9 km from the residence and workplace of 125 participating Beijing residents. Each participant was measured 6 times for biomarkers of autonomic function (heart rate, systolic and diastolic blood pressures), hemostasis (von Willebrand factor, soluble CD40 ligand, and P-selectin), pulmonary inflammation and oxidative stress (exhaled nitric oxide and exhaled breath condensate pH, malondialdehyde, and nitrite), and systemic inflammation and oxidative stress (urinary malondialdehyde and 8-hydroxy-2'-deoxyguanosine, plasma fibrinogen, and white blood cells). Linear mixed models were used to estimate associations of biomarkers with UFPs and PM2.5 measured 1-7 days prior to biomarker measurements (lags). We found that the correlation coefficient for UFPs at two locations (similar to 9 km apart) was 0.45, and at the same location, the correlation coefficient for PM2.5 vs UFPs was -0.18. Changes in biomarker levels associated with increases in UFPs and PM2.5 were comparable in magnitude. However, associations of certain biomarkers with UFPs had different lag patterns compared to those with PM2.5, suggesting that the ultrafine size fraction (<= 100 nm) and the fine size fraction (similar to 100 nm to 2.5 mu m) of PM2.5 are likely to affect PM-induced pathophysiological pathways independently.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available