4.7 Article

Analytical mode decomposition with Hilbert transform for modal parameter identification of buildings under ambient vibration

Journal

ENGINEERING STRUCTURES
Volume 59, Issue -, Pages 173-184

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2013.10.020

Keywords

System identification; Closely spaced modes; Analytical mode decomposition; Ambient vibration; Hilbert transform; Random decrement technique

Funding

  1. National Science Foundation [CMMI0409420]
  2. China Scholarship Council [NSCIS-[2007]-3020]

Ask authors/readers for more resources

A new analytical mode decomposition method in combination with the conventional random decrement technique is proposed for modal parameter identification under ambient vibration. The random decrement technique is used to extract the free vibration information from ambient vibration including closely-spaced modes. The analytical mode decomposition is developed with Hilbert transform to decompose the extracted free vibration with closely spaced natural frequencies into a series of modal responses from which modal parameters are evaluated. Emphasis in this study is placed on the characterization of frequency resolution, time duration effect, identification accuracy, and experimental validation of the new method. An energy error index is introduced and defined as the ratio between the squared modal response error and the exact modal energy over the response duration, accounting for the effects of both response amplitude and phase. Parametric studies with a 2-story building demonstrated a reduction of the energy error index from 88% with ambient vibration to 7.5% with 20-s free vibration, corresponding to a natural frequency space index of 0.033. The maximum error of the identified frequencies in all cases is less than 1%. At a frequency space index of 0.05, the energy error indices are less than 20% and 5% using 1-s and 7-s free vibration, respectively. The new method is then validated with shake table testing of a 3-story building frame installed with a tuned mass damper, and applied to a 36-story shear building with a 4-story light appendage with closely spaced modes. Both experiments and simulations showed high accuracy and effectiveness of the new method for building system identification from ambient vibration even when 5% noise. (C) 2013 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available