4.7 Article

The fracture mechanisms of main cable wires from the forth road suspension

Journal

ENGINEERING FAILURE ANALYSIS
Volume 31, Issue -, Pages 430-441

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.engfailanal.2013.01.025

Keywords

Suspension bridge; Galvanised steel wire; Corrosion fatigue; Hydrogen embrittlement; Metallurgical examination

Ask authors/readers for more resources

The mechanism of galvanised wire strand fracture in suspension bridge main cables is still a subject which is not fully understood and is often the focus of research studies. This current study presents findings from the third cable inspection performed on the Forth Road Bridge in Scotland. An extensive test programme which included metallographic wire examination, tensile testing and cyclic fatigue testing was carried out. From the findings a discussion of the possible mechanisms contributing to wire failure is provided. The results showed that tensile strength reduction is due to extremely localised corrosion, which propagates perpendicular cracks within individual wires, and was not directly related to the general corrosion severity classification used in the industry. The required depth of propagation to cause fracture was shown to range from as low as 150 mu m, up to the radius of the wire. Possible mechanisms of crack initiation and propagation are considered and include; pitting corrosion, hydrogen assisted cracking, branched cracking and corrosion-fatigue. (C) 2013 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available