Journal
ENERGY CONVERSION AND MANAGEMENT
Volume 77, Issue -, Pages 108-117Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2013.09.026
Keywords
Waste heat recovery; Organic Rankine Cycle; Exergy; Pinch point analysis; Low temperature
Categories
Ask authors/readers for more resources
Energy, in conjunction with exergy, analysis of a waste heat driven Organic Rankine Cycle (ORC) is performed. Using actual plant data, performance of the cycle and pinpoint sites of primary exergy destruction are assessed. Furthermore, variations of energy and exergy efficiencies of the system with evaporator/condenser pressures, superheating and subcooling are illustrated. It is observed from the analysis that, the energy and exergy efficiencies of the system are 10.2%; 48.5% and 8.8%; 42.2%, respectively, for two different actual cases. Exergy destruction of subcomponents is also quantified. The components with greater exergy destructions to lower one can be listed as evaporator, turbine, condenser and pump. Evaporation pressure has significant effect on both energy and exergy efficiencies. Pinch-point analysis is, also performed to determine effects of heat exchange process, in the evaporator, on the net power production. (C) 2013 Elsevier Ltd. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available