The role of areal heat capacity and decrement factor in case of hyper insulated buildings: An experimental study

Journal

ENERGY AND BUILDINGS
Volume 176, Issue -, Pages 310-324

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2018.07.034

Keywords

Thermal inertia; Internal areal heat capacity; Experimental study; Decrement factor

Ask authors/readers for more resources

Extensive simulation-based researches have highlighted the importance of placing a massive layer in the inner side of hyper insulated CLT buildings in the interest of optimize their thermal performance on an annual basis. The purpose of the present research is to experimentally evaluate the thermal responsiveness of multi layered and highly insulated CLT building envelopes characterized by different combination of two dynamic parameters, namely the internal areal heat capacity kappa(1) and the decrement factor f. An on-site monitoring campaign was extensively performed, during summer and winter seasons, on an unoccupied and windowless test room in Central Italy. Four internal linings were simultaneously tested on the south facing wall: plasterboard (as a baseline reference), two dry clay panels with different thickness and a combination of brick and an additional internal insulation layer. Over the year, the indoor microclimate was exposed to three different occupancy/solar gains profiles, identified with Test 1-3 and supplied to the room by three electric radiators. During Test 1 and Test 2 (summer and autumn, respectively), the results have shown the limits of the adoption of lightweight and hyper-insulated external walls with high internal areal heat capacity and very low decrement factor in the Mediterranean area. In fact, such typology exhibits the highest surface temperatures, with daily maximum around 28 degrees C and nocturnal minimum approximately 1.5 degrees C lower. Moreover, increasing the thermal resistance of a wall by adding an insulated lining partially inhibits the proper storage ability on the inner side, causing the release of more heat inside the test room. Conversely in winter (Test 3), such configuration was found to have a positive response in terms of stored heat quota, with respect to the released one. The solution that guaranteed the best thermal performance on annual basis under different indoor boundary conditions was the wall envelope characterized by average inertial properties, notably kappa(1) equal to 33 kJ/(m(2)K) and a decrement factor of 0.072. (C) 2018 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available