Journal
ENERGY AND BUILDINGS
Volume 43, Issue 12, Pages 3635-3645Publisher
ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2011.09.038
Keywords
Double-skin facade (DSF); EnergyPlus; Simulation; Validation; Measurement
Ask authors/readers for more resources
Currently, several whole-building simulation tools (e.g., esp-r, EnergyPlus, TRNSYS, TAS, IES VE, IDA ICE, VA114, BSim, etc.) are used to assess the energy performance of double-skin facade (DSF) buildings. The aforementioned tools are well suited to assess energy performance of conventional building systems or whole buildings; however, it is questionable whether such tools can accurately describe the transient heat and mass transfer phenomena that occur in the complex three-dimensional geometry of DSFs. This paper describes an empirical validation of the EnergyPlus simulation tool for performance simulation of a DSF. A series of experiments were conducted for cavity airflow and thermal behavior of the DSF and then compared with simulation outputs. In this paper, it is shown that there are significant differences in both thermal and airflow behavior of DSFs between the measurements and simulation predictions by EnergyPlus. This study investigates three cases causing the differences and elucidates what should be considered when modeling DSFs using EnergyPlus. (C) 2011 Elsevier B.V. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available