Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier

Journal

ENERGY AND BUILDINGS
Volume 41, Issue 1, Pages 51-55

Publisher

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2008.07.007

Keywords

Brick wall; Interior thermal insulation system; Hydrophilic mineral wool; Water vapour retarder; Hygrothermal performance; On-site assessment

Funding

  1. Ministry of Education, Youth and Sports of the Czech Republic [MSM: 6840770031]

Ask authors/readers for more resources

On-site assessment of hygric and thermal performance of an interior thermal insulation system on the basis of hydrophilic mineral wool is presented in the paper. The system is applied during the Summer period oil a brick-built house from the end of 19th century. Hygrothermal testing is done during the time period of 4 years. The reconstructed building envelope exhibits very good hygrothermal performance. The thermal resistance increases approximately two times. Water condensation is never observed inside the envelope during the whole testing period. A comparison with the previous experiment in semi-scale conditions which was performed for similar insulation system constructed during the winter season shows that the precedence should be given to the application of the system in summer period as it is more considerate to the old masonry. (C) 2008 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available