4.7 Article

Experimental and simulated study on a novel compressed air drying system using a liquid desiccant cycle

Journal

ENERGY
Volume 162, Issue -, Pages 60-71

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2018.07.183

Keywords

Compressed air; Drying; Liquid desiccant; Waste heat recovery

Funding

  1. National Natural Science Foundation of China [51776036]
  2. National Key Research and Development Plan Project of China [2018YFC0705300]
  3. National Program for Support of Top-notch Young Professionals
  4. Fundamental Research Funds for the Central Universities

Ask authors/readers for more resources

A new method using liquid desiccant in compressed air drying was put forward in our previous work. However, only the test bench of the pressurized dehumidifier was established and analyzed. And the regenerator was not established, so the proposed system was not complete. Thus, the system performance of the complete system is unknown. In this paper, the experimental bench and steady-state mathematical model of the complete system are established to investigate the system performance. The dew point of compressed air is -2.4 degrees C (0.8 MPa) in experiments, indicating dryness could meet needs of various industries which use cooling dehumidification. Besides, the average regeneration temperature is 72.9 degrees C in experiments, indicating using waste heat from the air compressor to drive solution regeneration is feasible. Moreover, effect of different key parameters, including solution flow rate, solution temperature and ambient conditions on system performance is analyzed by mathematical model. It can be concluded that relative higher solution flow rate, lower inlet solution temperature of dehumidifier and higher inlet solution temperature of regenerator can get a lower humidity ratio. The selected regeneration temperatures in different ambient conditions are 70 degrees C (summer), 39 degrees C (winter), 60 degrees C (transitional season) respectively, which can be used as a reference for the actual operation. (C) 2018 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available