4.7 Article

Performance study of solar air heater having v-down discrete ribs on absorber plate

Journal

ENERGY
Volume 55, Issue -, Pages 939-955

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2013.03.068

Keywords

Smooth and roughened duct solar air heater (collector); V-down discrete rib roughness; Thermal efficiency; Effective efficiency

Ask authors/readers for more resources

The paper presents results of an experimental study of thermo-hydraulic performance of a solar air heater with 60 degrees v-down discrete rib roughness on the airflow side of the absorber plate along with that for a smooth duct air heater. The enhancement in the thermal efficiency due to the roughness on the absorber plate is found to be 12.5-20% depending on the airflow rate; higher enhancement is at the lower flow rate. The experimental data have been generated and utilized to validate a mathematical model, which can be utilized for design and prediction of performance of both smooth and roughened air heaters under different operating conditions. The results of a detailed thermo-hydraulic performance study of solar air heater with v-down discrete rib roughness using the mathematical model are also presented along with the effect of variation of various parameters on the performance. (C) 2013 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available