Quantitative Measurement of Full-Length and C-Terminal Proteolyzed RBP4 in Serum of Normal and Insulin-Resistant Humans using a Novel Mass Spectrometry Immunoassay

Journal

ENDOCRINOLOGY
Volume 153, Issue 3, Pages 1519-1527

Publisher

OXFORD UNIV PRESS INC
DOI: 10.1210/en.2011-1750

Keywords

-

Funding

  1. National Institutes of Health [R37 DK43051, R24 DK083938, T32 DK07516, KO8 DK090149, R42 DK071290, RO3 DK080195]
  2. Doris Duke Clinical Scientist Development Award
  3. Takeda Pharmaceutical

Ask authors/readers for more resources

Serum retinol-binding protein 4 (RBP4) levels are increased in insulin-resistant humans and correlate with severity of insulin resistance in metabolic syndrome. Quantitative Western blotting (qWestern) has been the most accurate method for serum RBP4 measurements, but qWestern is technically complex and labor intensive. The lack of a reliable, high-throughput method for RBP4 measurements has resulted in variability in findings in insulin-resistant humans. Many commonly used ELISAs have limited dynamic range. Neither the current ELISAs nor qWestern distinguish among full-length and carboxyl terminus proteolyzed forms of circulating RBP4 that are altered in different medical conditions. Here, we report the development of a novel quantitative mass spectrometry immunoaffinity assay (qMSIA) to measure full-length and proteolyzed forms of RBP4. qMSIA and qWestern of RBP4 were performed in identical serum aliquots from insulin-sensitive/normoglycemic or insulin-resistant humans with impaired glucose tolerance or type 2 diabetes. Total RBP4 qMSIA measurements were highly similar to qWestern and correlated equally well with clinical severity of insulin resistance (assessed by clamp glucose disposal rate, r = -0.74), hemoglobin A1c (r = 0.63), triglyceride/high-density lipoprotein (r = 0.55), waist/hip (r = 0.61), and systolic blood pressure (r = 0.53, all P < 0.001). Proteolyzed forms of RBP4 accounted for up to 50% of total RBP4 in insulin-resistant subjects, and des(Leu)RBP4 (cleavage of last leucine) correlated highly with insulin resistance (assessed by glucose disposal rate, r = -0.69). In multiple regression analysis, insulin resistance but not glomerular filtration rate was the strongest, independent predictor of serum RBP4 levels. Thus, qMSIA provides a novel tool for accurately measuring serum RBP4 levels as a biomarker for severity of insulin resistance and risk for type 2 diabetes and metabolic syndrome. (Endocrinology 153: 1519-1527, 2012)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available