4.6 Article

An ultrasensitive electrochemical immunosensor for the detection of salbutamol based on Pd@SBA-15 and ionic liquid

Journal

ELECTROCHIMICA ACTA
Volume 69, Issue -, Pages 79-85

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2012.02.073

Keywords

Sandwich-type immunosensor; Salbutamol antigen; Graphene sheets; Pd@SBA-15; Ionic liquid

Funding

  1. Natural Science Foundation of China [21075052, 21175057]
  2. Natural Science Foundation of Shandong Province [ZR2010BM030, ZR2010EM063]
  3. Key Subject Research Foundation of Shandong Province [XTD1105]
  4. Science and Technology Key Plan Project of Shandong Province [2010GSF10628]
  5. National Water Pollution Control and Management Technology Major Projects [2008ZX07422-001-5-1]
  6. Special Research and Development Environmental Protection Industry of Shandong Province
  7. Science and Technology Development Plan Project of Jinan City [201004015]

Ask authors/readers for more resources

A sandwich-type electrochemical immunosensor for the ultrasensitive detection of the salbutamol (SAL) antigen based on sodium dodecylbenzene sulfonate-functionalized graphene sheets (SDBS-GS), Pd nanoparticles in functionalizecl SBA-15 (Pd@SBA-15) and ionic liquid (IL) is described. The primary SAL antibody (Ab(1)) can be covalently attached to the sulfonic groups of SOBS-GS through the amines of Ab(1) with an acyl chloride cross-linking reaction. Pd@SBA-15 was prepared by adsorption of H2PdCl4 onto the SBA-15 surface; the adsorbed H2PdCl4 was then reduced to Pd nanoparticles with sodium borohydride. Pd@SBA-15 was conjugated to the secondary SAL antibody (Ab(2)) through glutaraldehyde. IL was added to the mixture of Pd@SBA-15 and Ab(2) to promote electron transport. The synergistic effect between IL and Pd@SBA-15 retained the bioactivity of Ab(2). The sensitivity of the sandwich-type immunosensor using Pd@SBA-15/Ab(2)/IL for the detection of SAL was much higher than those that used either SBA-15/Ab(2) or Pd@SBA-15/Ab(2). Under optimal conditions, the electrochemical immunosensor exhibited a wide working range from 0.02 to 15.0 ng/mL with a detection limit of 7 pg/mL. The precision, reproducibility and stability of the immunosensor were acceptable. The proposed strategy could be easily extended to fabricate immunosensors for other tumor markers. (C) 2012 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available