4.6 Article

Electrodeposition of gold-platinum alloy nanoparticles on carbon nanotubes as electrochemical sensing interface for sensitive detection of tumor marker

Journal

ELECTROCHIMICA ACTA
Volume 56, Issue 19, Pages 6715-6721

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2011.05.066

Keywords

Amperometric immunosensor; Alpha-fetoprotein (AFP); Multi-walled carbon nanotubes (MWCNTs); Gold-platinum alloy nanoparticles (Au-PtNPs); Horseradish peroxidase (HRP)

Funding

  1. National Natural Science Foundation of China [21075100]
  2. Ministry of Education of China [708073]
  3. Natural Science Foundation of Chongqing [CSTC-2009BA1003]
  4. Specialized Research Fund for the Doetoral Program of Higher Education [20100182110015]
  5. High Technology Project Foundation of Southwest University, China [XSGX02]

Ask authors/readers for more resources

A novel electrochemical sensing interface, electrodeposition of gold-platinum alloy nanoparticles (Au-PtNPs) on carbon nanotubes, was proposed and used to fabricate a label-free amperometric immunosensor. On the one hand, the multiwalled carbon nanotubes (MWCNTs) could increase active area of the electrode and enhance the electron transfer ability between the electrode and redox probe: on the other hand, the Au-PtNPs not only could be used to assemble biomolecules with bioactivity kept well, but also could further facilitate the shuttle of electrons. In the meanwhile, horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) was employed to block the possible remaining active sites and avoid the nonspecific adsorption. With the synergetic catalysis effect of Au-PtNPs and HRP towards the reduction of hydrogen peroxide (H(2)O(2)), the signal could be amplified and the sensitivity could be enhanced. Using alpha-fetoprotein (AFP) as model analyte, the fabricated immunosensor exhibited two wide linear ranges in the concentration ranges of 0.5-20 ng mL(-1) and 20-200 ng mL(-1) with a detection limit of 0.17 ng mL(-1) at a signal-to-noise of 3. Moreover, the immunosensor exhibited good selectivity, stability and reproducibility. The developed protocol could be easily extended to other protein detection and provided a promising potential in clinical diagnosis application. (C) 2011 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available