4.4 Article

Comparison between drug screening by immunoassay and ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry in post-mortem urine

Journal

DRUG TESTING AND ANALYSIS
Volume 7, Issue 5, Pages 420-427

Publisher

WILEY
DOI: 10.1002/dta.1683

Keywords

drugs of abuse; urine; drug screening; time-of-flight mass spectrometry; immunoassay

Funding

  1. EU Commission [JUST/2011/DPIP/AG/3597]

Ask authors/readers for more resources

Immunoassay is currently the most common approach for urine drug screening. However, the continuous emergence of new psychoactive substances (NPS) and their low urinary concentrations have challenged the scope and sensitivity of immunoassays. Consequently, specialized toxicology laboratories rely more and more on mass spectrometry (MS) based techniques. Ultra-high performance liquid chromatography/high-resolution time-of-flight mass spectrometry (UHPLC-HR-TOF-MS) is an especially attractive technique for comprehensive drug screening. The objective was to compare the performances of immunoassay and UHPLC-HR-TOF-MS in terms of scope, flexibility, sensitivity, and reliability of substance identification. A total of 279 post-mortem urine samples were analyzed using a method representative of each technique. The immunoassay method was an Emit II Plus enzyme immunoassay for the following drug groups: amphetamines, benzodiazepines, buprenorphine, cannabis, and opiates. The UHPLC-HR-TOF-MS method was a recently published method covering hundreds of drugs: conventional drugs of abuse, abused prescription drugs, and NPS of various classes. UHPLC-HR-TOF-MS produced a lower number of false positive (FP) results for the drug groups covered by immunoassay. Many of the false negative (FN, n=40) and FP (n=22) immunoassay results were obviously due to the higher cut-off concentrations and interfering matrix, respectively. Moreover, the wider scope of UHPLC-HR-TOF-MS allowed detection of NPS and prescription drugs. UHPLC-HR-TOF-MS gave FP results related to a few particular substances. The future option of adjusting all compound-specific reporting parameters individually would allow the method's sensitivity and specificity to be fully exploited. Copyright (c) 2014 John Wiley & Sons, Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available