4.4 Article

Simultaneous quantification of acetaminophen and structurally related compounds in human serum and plasma

Journal

DRUG TESTING AND ANALYSIS
Volume 6, Issue 5, Pages 451-460

Publisher

WILEY-BLACKWELL
DOI: 10.1002/dta.1527

Keywords

acetaminophen; LC-MS; MS; immunoassay; metabolites; serum; plasma

Funding

  1. Alfried Krupp von Bohlen und Halbach-Stiftung

Ask authors/readers for more resources

The method described in this study allows the simultaneous quantification of acetaminophen (APAP) and nine structurally related compounds, namely acetaminophen metabolites and structurally similar analogs (acetaminophen-glucuronide [APG], -sulfate [APS], mercapturate [APM], -cysteine [APC], p-phenetidine, phenacetin), antidote (N-acetylcysteine, NAC), and two tricyclic antidepressants (imipramine and amitryptiline). Due to the relatively high serum concentration levels in the mu g/ml range, matrix effects were simply minimized by dilution. The samples were diluted with water and disulfide bonds between serum proteins and analytes reduced using tris(2-carboxyethyl)phosphine. Chromatographic separation of the analytes was achieved by gradient elution using a pentafluorphenyl (PFP) column with subsequent detection by electrospray ionization (ESI) triple quadrupole mass spectrometry in positive and negative ionization multiple reaction monitoring (MRM) modes. Quantification was performed by means of deuterated analogues of the analytes as internal standards. Total run time of the assay was 19min. The method was fully validated and allowed quantification of the analytes with lower limits of quantification between 50 and 0.5ng/ml. The calibration curves were linear over the range 0.1-100 mu g/ml for APAP, APG, NAC, p-phenetidine and phenacetin, 0.03-50 mu g/ml for APS, and 0.01-10 mu g/ml for APM, APC, imipramine and amitriptyline with correlation coefficients r(2)>0.99. The intra-assay precision was 5% for all analytes except NAC (CV<10%). The inter-day precision was 10% for all analytes except NAC (inter-assay precision <11%). This method was used to analyze 77 patient and spiked samples and results were consistent with expected values from a round robin test. Copyright (c) 2013 John Wiley & Sons, Ltd.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available